What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION CPCP FINDING: CORROSION ON SHEARCLIP ON FR86 BETWEEN STGR 28R / 27R AT AFT CARGO; SUMMARY: SHEAR CLIP ON FR86 BETWEEN STGR 28R / 27R AT AFT CARGO WAS REPLACED PER EMB 190 SRM 51-43-01 PAR. 5,EMB 190 SRM 51-41-02 PAR. 6 AND EMB 190 SRM 51-41-01 PAR. 6 REF. TECHOPSMX WO N216JB/2075/E190/BRIDGE CHECK NRC 00058 TECH: CORONADO LOPEZ 201217491 INSP: JIMENEZ DE LA CRUZ 202268641 (CONSIDERED AS A MAJOR REPAIR)