Service difficulty report · Service Panel · Emb ERJ190100IGW

Difficulty date
January 6, 2023
Submitted
January 12, 2023
Operation
Air carrier
Aircraft
N198JB
Make and model
Emb ERJ190100IGW
Aircraft serial
021
Aircraft time
43,399 hours, 28,385 cycles
Part
Service Panel
Condition
Corroded
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING HEAVY MAINTENANCE: CORROSION IN THE INTERNAL DOUBLER AND EXTERNAL SKIN OF THE WASTE SERVICE PANEL WAS FOUND; REF TOMX W/O 2108 NR 00024. CORROSION IN EXTERNAL SKIN WAS REMOVED AND EVALUATED OT=0.098" AND MRT= 0.094" THEREFORE IS WITHIN LIMITS PER EMB-190 SRM 51-12-01, SRM 51-10-03, AND SRM 53-23-60/AD51. CORROSION IN THE INTERNAL DOUBLER WAS REMOVED AND EVALUATED OT=0.098" AND MRT =0.040" THEREFORE IT'S OUT OF LIMITS AND WAS REPAIRED PER EMB-190 SRM 51-12-01, SRM 51-10-03, SRM 53-23-60/AD51 AND SRM 53-23-60 REPAIR 51. COMPLETED BY: