What was found
FLT#22, MBJ-MCO.' HAD A LEVEL 2 FUMES IN CLIMB OUT. TURNED OFF PACK 2 AND THE FUMES SEEMED TO DISSIPATE; INTEROGATED PILOT SURVEY. ALL POINTS TOWARDS DEICE FLUID CONTAMINATION INSPECTED #2 PACK AREA FOUND NO EVIDENCE OF GLYCOL. FOUND DEICE RESIDUE ON RH SIDE OF WTB FAIRING, TAIL SECTION, AND INSIDE OF THS SERVICE AREA.'