What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER ATTACHMENT AR EA CONTINUITY FITTING LH SIDE, CRACK LENGTH IS 0.200 INCH APPROX, IN COCKPIT; REF N/R 2022-662818 WO 2022454/1, R&R CONTINUITY FITTING FROM FRAME 2 WINDSHIELD CENTER POST LOWER ATTACHMENT AREA LH SIDE IAW SRM 51-42-11, AND SRM 51-72-11 AND REPAIR INSTRUCTION R53112919. PERFORMED ROTO TEST INSPECTION ON OPEN FASTENER HOLES 3EA PER NTM 51-10-01 TO ACCOMPLISH REPAIR INSTRUCTION R53112919 ISSUE D SHEET 23 OF 27.