What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16RH SIDE INTERCOSTAL FITTING ON HOLE 3 AT DOOR STOP POSITION 7 CRACK DIRECTION IS 9 O'CLOCK AT FWD GALLEY AREA (1EA); REF: ARM W/O 2-33 12/1 N/R 2023-98134 REMOVED AND REPLACED NEW INTERCOSTAL FITTING AND FASTENERS LOCATED ON FRAME 16 RH SIDE FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112300.