What was found
DURING HEAVY MAINTENANCE: CORROSION STRINGER 42R AT FR32 PLUS 1 INCH IN FWD CARGO COMPARTMENT REF. MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD: NR-00027 ) PERFORMED PERMANENT REPAIR LOC. STR42R AT FR32 PLUS 1INCH IN FWD CARGO COMPARTMENT IAW A320 SRM 51-21-13-300-018 AND DWG D53231917 THIS REPAIR IS CATEGORY A. MEASURES OF CORROSION ARE L=1.205IN W=0.749IN. ALL WORK ACCOMPLISHED ON AE NON-ROUTINE #2023-98336 W/O #2023 12/1. WORK ACCOMPLISHED BY AE TECH #8630615. RII BY AE QC 183.