What was found
DURING HEAVY MAINTENANCE: TRANSFERRED FROM NRC:00069; DUE TO ORIGINAL TASK BEING VOIDED (021:53-10-027-0384): INITIAL INSPECTION: [CPCP FINDING] CORROSION IN SEAT TRACK LOCATED BTW FR17 AND FR18, Y=250.0 AT FWD FUSELAGE FLOOR STRUCTURE; (RESOLVED ON W/O: 1241589 TASKCARD: NR-00002 ) CORROSION IN SEAT TRACK LOCATED BTW FR17 AND FR18, Y=250.0 AT FWD FUSELAGE FLOOR STRUCTURE WAS REMOVED PER EMB 190 SRM 51-12-01, SRM 51-10-03, EVALUATED FOR EXCESSIVE DAMAGE AND WAS REPLACED THE SEAT TRACK BEAM RH LOCATED BTW FR12 AND FR21 PER EMB 190 SRM 51-10-02, SRM 51-41-01, SRM 51-41-02, SRM 51-43-03 AND SRM 51-43-04. ALL WORK ACCOMPLISHED ON TOMX N/R #0115. ACOMPLISHED BY TOMX TECH #10000370, RII BY TOMX QC # 438721.