Service difficulty report · Bleed Valve · Airbus A321271N

Difficulty date
March 30, 2023
Submitted
March 31, 2023
Operation
Air carrier
Aircraft
N2142J
Make and model
Airbus A321271N
Aircraft serial
10254
Aircraft time
6,558 hours, 1,242 cycles
Engine
Iae PW1133GAJM
Engine time
6,558 hours, 1,242 cycles
Part
Bleed Valve
Part number
70645A020001
Part serial
7064503524
Condition
Broken
Location
Engine-1
Part time
7,686 hours, 2,342 cycles
Stage of operation
IN
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT#523, JFL-LAX. (ETOPS) 'ENG1 HPV LOCKOUT PIN BROKEN IN DEACTIVATED POSITION; REMREP ENG1 BLEED HPV PER AMM REF 36-11-51. REF LOGPAGE 3569615, ITEM 2 (RAN ENG 1 + 2 PER 71-00-00-860-323A. AND OPS CHKECK OF #1 ENG HPV PER 36-11-51, C/W POWER ASSURANCE TEST PER 71-00-00-310-806A. NO BLEED FAULT NOTED NO ECAM.) FOR OPS CHECK.'