What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHME NT AREA CONTINUITY FITTING LH SIDE, CRACK LENGTH IS 0.200 INCH, IN COC KPIT (1 EA); REF AEROMAN WO 2023-68626 WO 2023 1/1 REMOVED AND REPLACED CONTINUITY FITTING LH SIDE LOCATED WINDSHIELD CENTER POST LOWER NODE ATTACHMENT AREA IAW A320 SRM 51-42-11 AND REPAIR INSTRUCTION R53112919. TOOL USED TORQUE P/N: QD1R200, S/N: P916907963, DUE DATE APR-29-2023; PN NORTEC 600D SN 220272712 DUE DATE DEC-17-2023. DONE BY L. OSTORGA 8619517.