What was found
DURING HEAVY MAINTENANCE: 36WR OXYGEN GENERATOR FAILED MANUAL DROP TEST; PERFORMED TSM 35-23-00-81-807A AND WIRING TERMINAL BLOCK 7372VT 141 WIRING NO 3523-1114 POSITION K WAS FOUND LOOSE IAW ESPM 20-52-11 AMM 35-73-06 PERFORMED CONNECTED CORRECTLY WIRING ON TERMINAL BLOCK 7312VT141 WIRING NO 3523-114 IAW AMM 35-23-06 AND ESPM 70-44-51 AND PERFORMED OPERATIONAL TEST CHECK OF MANUAL MASK RELEASE IAW AMM 35-23-00-710-001-A TEST IS OK.'