What was found
DURING HEAVY MAINTENANCE: DURING THE ACCOMPLISHMENT OF THE SAFETY PRECAUTIONS FOR DOOR SLIDES WE FOU ND DOOR (841) RESERVOIR VALVE HOLE MISALIGNED TO INSTALL THE LOCK PIN; REF TO AEROMAN WO 2023 243/1 NR 2023-345034, REMOVED AND REPLACED ESCAPE SLIDE RAFT AT PASSENGER CREW DOOR 841 AT FWD GALLEY AREA IAW AMM 25-62-00-710-001-A ITEM 3.A THRU 4.A.(12), AMM 25-62-00-710-001-A STEP 5.A.(1), AMM 52-10-00-610-001-A STEP 1 THRU 4. B, AMM 52-10-00-614-001-A, AMM 25-62-44-400-803-A, AND AMM 33-51-00-710-001-A PERFORMED OPERATIONAL TEST IS OK.