What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 LH DOOR STOP 1 HOLE POSITION IS INBD/LOWER DIRECTION OF CRACK IS 6 O'CLOCK; (RESOLVED ON W/O: 1209138 TASKCARD: NR-00025 ) PERFORMED PERMANENT REPAIR LOC. FR68LH AT LEVEL DOOR STOP FITTING 1 IAW A320 SRM 51-41-12-300-008 AND SRM 51-41-12-300-011. THIS REPAIR IS CATEGORY B, WITH THE INSPECTION THRESHOLD FORM TIME OF ADL/REPAIR EMBODIMENT ON AREA 1 60000FC/FH NOT RELEVANT. SUBSEQUENT INSPECTIONSTBD, INSPECTION METHOD TBD; INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT ON AREA 3 60000FC/FH NOT RELEVANT, SUBSEQUENT INSPECTION TBD, INSPECTION METHOD TBD. FUR-A320-53-00744 ASSIGNED.