As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (FWD RH EEH DOOR 843) CRACK L=0.125 INCH APPROX; REF: ARM W/O 2023 128/1 N/R 2023-355650 REMOVED AND REPLACED FRAME SEGMENTS (1) FWD RH EEH ON EMERGENCY EXIT DOOR 843 RH SIDE THIS JOB IS ACCOMPLISHED ON TASK CARD A320-52-1144-02 AND EC .A320-52-1144.