What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON WEB FRAME 20 COMMON TO DOOR STOP FITTING 1 FROM HO LE H1 LOCATED AT FRAME 20 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1.8MM APPROX); REF. AEROMAN WO 2023 273/1 NR 481370-- REMOVED AND RE-INSTALLED INTERCOSTAL COMMON TO DOOR STOP FITTING 1 FROM HOLE H1 LOCATED AT FRAME 20 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1MM APPROX ) IAW A320 SRM 51-42-11 AND DWG D53114097. TOOL USED SMALL HOLE GAUGES P/N: 154-901, S/N:AE-411361, DUE DATE: JAN-27-2024 MICROMETERS P/N:293-345-30, S/N:71699858; DUE DATE:NOV-21-2023, EDDY CURRENT EQUIPMENT, PN: NORTEC 600D, SN: 220272512 DUE DATE DEC-17-2023. DONE BY Y. MENA 8672120.