What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOL E H1 LOCATED AT FRAME 16 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1 MM APPROX ); REF AEROMAN WO 2023 273/1 NR 2023-481369 --REMOVED AND REPLACED INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOLE H1 LOCATED AT FRAME 16 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1MM APPROX ) IAW A320 SRM 51-42-11 AND DWG D53114097. TOOL USED: SMALL HOLE GAUGES P/N:154-901, S/N:AE-411361, DUE DATE: JAN-27-2024, MICROMETERS P/N:293-345-30;S/N:71699858; DUE DATE:NOV-21-2023, EDDY CURRENT EQUIPMENT PN NORTEC 600D SN 220272512 DUE DATE DEC-17-2023. DONE BY Y. ME.