What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOL E H3 LOCATED AT FRAME 16 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1 .1MM APPROX); REF AEROMAN WO 2023 273/1 NR 481368 -- REMOVED AND REPLACED INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOLE H3 LOCATED AT FRAME 16 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 1.1 MM APPROX ) IAW A320 SRM 51-42-11 AND DWG D53114097. TOOL USED SMALL HOLE GAUGES P/N:154-901;S/N:AE-411361; DUE DATE: JAN-27-2024, MICROMETERS P/N:293-345-30;S/N:71699858; DUE DATE:NOV-21-2023, EDDY CURRENT EQUIPMENT PN NORTEC 600D SN 220272512 DUE DATE DEC-17-2023. DONE BY Y. MENA 8672120 CHECKED BY