What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOL E H1 LOCATED AT FRAME 16 LH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 0 .73MM APRROX); REFERENCE AEROMAN WO2023 273/1 NR481366 -- REMOVED AND REPLACED INTERCOSTAL COMMON TO DOOR STOP FITTING 7 FROM HOLE H1 LOCATED AT FRAME 16 RH SIDE AT FWD GALLEY AREA (CRACK LENGTH IS 0.73 MM APPROX ) IAW A320 SRM 51-42-11 AND DWG D53114097. TOOL USED SMALL HOLE GAUGES P/N:154-901;S/N:AE-411361; DUE DATE: JAN-27-2024, MICROMETERS P/N:293-344-30;S/N:71690646; DUE DATE:NOV-29-2023, EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D, SN: 210138203, CAL DUE DATE: JUN-09-2024. DONE BY Y. MENA 8672120.