Service difficulty report · Bleed Valve · Emb ERJ190100IGW

Difficulty date
October 24, 2023
Submitted
October 25, 2023
Operation
Air carrier
Aircraft
N236JB
Make and model
Emb ERJ190100IGW
Aircraft serial
035
Aircraft time
44,464 hours, 28,838 cycles
Part
Bleed Valve
Part number
10012463
Part serial
2016040011
Condition
Failed
Location
Nr 2 Engine
Part time
8,143 hours, 5,676 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT#1105, JFK-ORD. (AIRCRAFT PERFORMED AN AIR TURN BACK TO JFK) ' AT FL 220 W/ICINGS WE HAD A BLEED 2 FAIL EICAS. THIS LED TO THE CABIN LOSING PRESSURE. IT ENDED UP COMING BACK ON ONCE WE TURNED APU ON; TROUBLESHOT PER FIM TASK 36-10-00-810-810A. REMOVED AND REPLACED #2 NAPROSOV. OPS CHECK GOOD. NO FAULT NOTED AT THIS TIME. OK FOR CONT SVC. MULTIPLE BLEED CHECKS PERFORMED UNABLE TO DUPLICATE FAULT. REF AMM 36-11-03.'

More about the Emb ERJ 190-100 IGW