What was found
DURING HEAVY MAINTENANCE: FWD WET AREA FLOOR STRUCTURE TRACK RIGHT SUPPORT AT FRAME 1714 AND 13 Y+10.5 HAS CORROSION MARKED IN RED; BLENDED CORROSION ON RH SEAT TRACK AT FR-14 PER EMB 190 SRM 51-10-03 BLENDED AREA AT FR -13 MEASURES MATERIAL LOSS .019 ALLOWED LOSS .014 BLENDED AREA AT FR-14 MEASURES MATERIAL LOSS.031 ALLOWED LOSS.014 PART TO BE FOUND OUT OF LIMITS REQUIRES REPLACEMENT PER EMB SRM 53-10-10 REMOVED AND REPLACED RIGHT TRACK SUPPORT ON FWD WET AREA PER E-190SRM 51-40-08 ALL WORK ACCOMPLISHED ON EAMS WO H9271 NR 00128. (CONSIDERED AS A MAJOR REPAIR)