What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE IN OPEN FASTENER HOLE H1 OF INTERCOSTAL FITTING AT DOOR STOP FITTING 7 POSITION, CRACK DIRECTION ARE 6 AND 12 OCLOCK, CRACK DEPTH IS 0.120 INCH, AT FWD GALLEY AREA (2 EA); REF AEROMAN W/O 2023 280/1 WCC 2023-640742 REMOVED AND REPLACED INTERCOSTAL FITTING AND FASTENERS LOCATED FR 16 LH SIDE AT LEVEL DOOR STOP FITTING #7 IAW A320 SRM 51-42-11 AND DWG D53112300. WORK C/OUT BY AEROMAN TECH 8600804 RII: QC273.