What was found
DURING HEAVY MAINTENANCE: SECONDARY NRC: AFTER DOUBLER REMOVAL IN REF NRC 00042, CORROSION ON SHEAR CLIP ABOVE FR 88 BTW STGR 28RH/STGR27RH WAS FOUND; (RESOLVED ON W/O: 1260255 TASKCARD: NR-00028 ) REF TOMX W/O #2362, N/R # 00283.CORROSION ON SHEAR CLIP ABOVE FR 88 BTW STGR 28RH/STGR27RH WAS REMOVED PER EMB-190 SRM 51-10-03 AND SRM 51-12-01 AND FOUND OUT OF LIMITS PER EMB-190 SRM 51-75-16, THEREFORE IT WAS REPLACED PER EMB 190 SRM 51-41-01, SRM 51-41-02 AND SRM 51-43-03. ACCOMPLISHED BY TOMX TECH # 439821, TOMX QC #10000016.