What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING] CORROSION ON FRAME 80 BTW STRG 28R/27R AT AFT CARGO DOOR CUTOUT STRUCTURE; (RESOLVED ON W/O: 1260255 TASKCARD: NR-00012 ) CORROSION ON FRAME 80 BTW STRG 26R/27R WAS EVALUATED OUT OF LIMITS, THEREFORE WAS REPAIRED PER EMB-190 SRM 51-10-03, SRM 51-12-01, SRM 51-75-16 AND ETI-190-23-685 REV 1. ALL WORK ACCOMPLISHED ON TOMX WO # 2362 N/R # 00188. ACCOMPLISHED BY TOMX TECH # 10001734, TOMX QC # 299517.