As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLT#2288. (ETOPS) ' AIR 1 BLEED ABNORMAL PR ECAM AFTER START DID NOT RESET PER QRH PROCEDURE GATE RETURN; PERFORMED FUNCTIONAL TEST OF BLEED VALVES PER AMM 36-11-52 FOUND PRV VALVE AT FAULT. REMOVED AND REPLACED VALVE FIN 4001HA1. OPS CHECK GOOD PER AMM 36-11-52. A/C OK FOR SVC.'