What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHMENT INTERNAL AREA FROM UPPER TENSION BOLT RH SIDE, CRACK DIRECTION IS 10 OCLOCK, CRACK LENGTH IS 0.105 INCH, IN COCKPIT (1 EA); ALL WORK ACCOMPLISHED ON AE WO # 2023-279/1 NR # 2023-590631 ACCOMPLISHED THE REPAIR OF THE CRACKS FOUND AT THE WINDSHIELD FRAME CENTER POST UPPER FASTENERS LH AND RH COMMON AREA AND THE MIRROR FITTING REPAIR IAW REF /1/ AEM EA 53-0360-23 REV 0 (COVER PART 1 AND PART 2) AND JB EC A23-1068-01.