What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHEM ENT INTERNAL AREA FROM UPPER TENSION BOLT LH SIDE, CRACK DIRECTION IS 2 OCLOCK, CRACK LENGTH IS 0.135 INCH, IN COCKPIT (1 EA); ALL WORK ACCMPLISHED ON AE WO 2023-279/1 NR 2023-590628 ACCOMPLISHED THE REPAIR OF THE CRACKS FOUND AT THE WINDSHIELD FRAME CENTER POST UPPER FASTENERS LH AND RH COMMON AREA AND THE MIRROR FITTING REPAIR IAW REF /1/ AEM EA 53-0360-23 REV 0 (COVER PART 1AND PART 2) JB EC A23-1068-01.