What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUNDS (2EA) IN OPEN HOLE (1EA) H3 (LOWER INBOARD POS ) LOCATED ON DOORSTOP FITTING 7 FRAME 16 RH CRACK DIRECTION: 11 AND 12 OCLOCK, D1-D2= 0.166 INCH; D1-D2=0.105 INCH; REF AEROMAN WO 2023 464/1 NR 731941 PERFORMED PERMANENT REPAIR ON OPEN HOLE (1EA) H3 (LOWER INBOARD POS ) LOCATED ON DOOR STOP FITTING 7 FRAME 16 RH I.A.W. A320 SRM 53-11-12-300-010. FINAL DIAMETER OF HOLE BEFORE BUSH INSTALLATION IS 0.360 INCH. THIS REPAIR IS CLASSIFIED CATEGORY B AND MUST BE INSPECTED AT 12200FC / FH NOT RELEVANT FROM TIME OF ADL/REPAIR EMBODIMENT AND SUBSEQUENT INSPECTIONS AT INTERVALS OF 12200FC / FH NOT RELEVANT WITH INSPECTION METHOD NTM I.A.W. A320 SRI 53-11-12-205-005 TABLE 001. WORK ACC BT AEROMAN TECH 8671320 RII BY M PERAZA 329 FUR-A320-53-01077