As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING] CORROSION ON SHARE CLIP AT FR89 BTW STGR#29LH TO STGR#28LH AT CENTER FUSELAGE III; (RESOLVED ON W/O: 1267464 TASKCARD: NR-00082) REF TOMX WO# 2452 NR# 00314 : CORROSION ON SHARE CLIP AT FR89 BTW STGR#29LH TO STGR#28LH AT CENTER FUSELAGE III WAS REMOVED AND EVALUATED OUT OF LIMITS PER EMB-190 SRM 51-12-01,SRM 51-10-03 AND SRM 51-75-16. THEREFORE WAS REPLACED PER EMB-190 SRM 51-41-02 AND SRM 51-41-01.