What was found
DURING HEAVY MAINTENANCE: REFERENCE TOMAX WO 2452 NR# 00264 INITIAL INSPECTION : [CPCP FINDING] CORROSION IN SHEARCLIP AT FR 80 & STGR 29L-28L AT AFT CARGO COMPARTMENT; (RESOLVED ON W/O: 1267464 TASKCARD: NR-00032) REFERENCE TOMAX NR 00264 :CORROSION IN SHEARCLIP AT FR 80 & STGR 29L-28L AT AFT CARGO COMPARTMENT WAS REMOVED AND EVALUATED OUT OF LIMITS THEREFORE WAS REPLACED PER EMB190 SRM 51-12-01, SRM 51-10-03, SRM 51-75-16, SRM 51-41-01, SRM 51-41-02 AND SRM 51-43-03.