As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION (CPCP FINDING): CORROSION ON BEAM LOCATED BTWN FR13-19 AND Y=260LH AT FWD FUSELAGE FLOOR STRUCTURE; REF TOMEX NR00173 / JETBLUE WO1284057 NR-00013: CORROSION ON BEAM LOCATED BTWN FR13-19& Y=260LH AT FWD FUSELAGE FLOOR STRUCTURE WAS REMOVED PER EMB-190 SRM51-10-03;51-12-01, WAS MEASURED AND EVALUATED OUT OF LIMITS PER EMB-190 SRM 53-10-10 AD/51, THEREFO. (CONSIDERED A MAJOR REPAIR)