As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION(CPCP FINDING): CORROSION ON SHEAR CLIP FR83 BTWN STRG 27L-28L AT AFT CARGO COMPARTMENT; REF TOMEX NR 00225: CORROSION ON SHEAR CLIP FR83BTWN STRG27L/28L @ AFT CARGO COMPARTMENT WAS REMOVED PER EMB-190 SRM51-12-01;51-10-03 & EVALUATED OUT OF LIMITS PER EMB190 SRM 51-75-16. THEREFORE IT WAS REPLACED PER EMB 190 SRM-51-41-01;51-41-02;51-43-03.(CONSIDERED A MAJOR REPAIR)