As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING]: CORROSION ON CROSS BEAM LOCATED BTW FR14 AND Y=310RH TO Y=770RH AT FWD FUSELAGE FLOOR STRUCTURE.; REF. TOMEX NR00182/JETBLUE WO1284057 NR00021. CORROSION ON CROSS BEAM LOCATED BTW FR14 AND Y=310RH TO Y=-770RH AT FWD FUSELAGE FLOOR STRUCTURE WAS REMOVED PER EMB-190 SRM 51-12--01 AND SRM 51-10-03, IT WAS MEASURED ANDEVALUATED OUT OF LIMIT. (CONSIDERED A MAJOR REPAIR)