What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING]: CORROSION ON CROSS BEAM LOCATED BTW FR16 AND Y=1000LH TO Y=1170LH AT FWD FUSELAGE FLOOR STRUCTURE; REF. TOMEX NR00169/ JETBLUE WO 1284057 NR-00017 SUMMARY: CORROSION ON CROSS BEAM LOCATED BTW FR16 AND Y=1000LH TO Y=-1170LH AT FWD FUSELAGE FLOOR STRUCTURE WAS REMOVED PER EMB 190 SRM 51-12--01,SRM 51-10-03, WAS MEASURED AND EVALUATED OUT OF LIMITS PER EMB-190 SRM 51--75-16 AND NE 03-071, THEREFORE WAS REPAIRED PER ETI-190-24-035 REV ORIG AND ETD2024-190-004120 REV:/. WORK PERFORMED BY TECH. J. LUNA#10000210; INSPECTED BY J. GUTIEREZ # 10001841.