What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FRAME 16LH UPPER DOUBLE JOGGLE AREA HOLE 7, CRACK DIRECTION 2 OCLOCK AND CRACK DEPTH = 0.122 INCH.; (RESOLVED ON W/O: 1282303 TASKCARD: NR-00039) REF WO 2024-39/1,NR 2024-108497.PERFORMED REPAIR ON HOLE 7 LOCATED ON FR 16LH UPPER DOUBLE JOGGLE IAW A320 SRM 53-11-12-300-012. THIS REPAIR IS CATEGORY B AND MUSTE BE INSPECT ION THR ESHOLD FROM TIME OF A DL/REPAIR EMBODIMENT AT 6800 F/C (F/H NOT RELEVANT) SUB- SEQUENT INSPECTIONS AT INTERVALS 5900 F/C (F/H NOT RELEVANT) IAW A320 SRM SRI 53-11-12-205-008 TABLE 001. TOOL USED SMALL HOLE GAUGES P/N: 154-901, S/N: AE-412979, DUE DATE: AUG-06-2024, ELECTR OUTSIDE MICROMETER P/N: 293-344-30, S/N: 71735394, DUE DATE: DEC-29-2024.EDDY CURRENT FLAW P/N: NORTEC 600D, S/N: 210136506, DUE DATE: MAY-23-2024.COMBINATION GAGE P/N:CBG-6-1-N-1 S/N:40-485 DUE DATE:AUG-30-2024 AND MANDREL GAGE P/N:CBMG-6-1-N S/N:316832B DUE DATE:MAR-25-2024.ACC BY #8625412,INSP BY # 335 FUR-A320-53-01204.