What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON HOLE C, FR 16 DOUBLE JOGGLE AREA, CRACK DIRECTION AT 9 OCLOCK RH SIDE, CRACK DEPTH 0.145 INCHES, CONFIRM EACH INDICATION USING BOROSCOPE VIEW AS PER NTM 51-90-00; (RESOLVED ON W/O: 1280173 TASKCARD: NR-00024) PERFORMED REPAIR ON HOLE C LOC. DOUBLE JOGGLE AREA FR16 RH SIDE IAW SRM A320 53-11-12-300-012. THIS REPAIR IS CAT B WITH INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT: 6800FC (FH NOT RELEVANT). SUBSEQUENT INSPECTION AT INTERVALS UNTIL 60,000FC/FH NOT RELEVANT: 4,900FC(FH NOT RELEVANT). INSPECTION METHOD FOR LEADER HOLE: REFER TO TASK 53-11-12-300-012, FIGURE 014. INSPECTION METHOD FOR ASSOCIATED HOLE(S): REFER TO TASK 53-11-12-300-012 FIGURE 014 IAW SRI 53-11-12-205-008, TABLE 001.DONE BY AE TECH# 8606419 AE RII QC# 329. FUR-A320-53-01448.