What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON INTERCOSTAL FITTING FASTENER HOLE H3 DOOR ST OP FITTING #7 AREA FR 16 LH. CRACK DIRECTION 3 OCLOCK. CRACK D= 2.54 M M; REF AEROMAN WO 2024 131/1 WCC 2024-336941. REMOVED AND REPLACED INTERCOSTAL FITTING LOC. AT LEVEL DOOR STOP FITTING 7 FR16 LH IAW A320 SRM 51-42-11 AND DWG D53112300, DWG R53113118. THIS REPAIR IS CATEGORY A AND NOT FURTHER INSPECTION IS REQUIRED.