What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND IN OPEN FASTENER HOLE LOC. ON FR. 16 LH DOOR STOP FITTING Ñ7 LOWER I/B HOLE. CRACK LENGTH 0.197 INCH APPROX; (RESOLVED ON W/O: 1301603 TASKCARD: NR-00021) REF AE W/O# 2024-50/1. N/R# 2024-216461.PERFORMED REPAIR INTERCOSTAL FITTING LOC. FR16 LH DOOR STOP FITTING 7 IAW A320 SRM 53-11-12-300-010. THIS REPAIR IS CATEGORY A NO REQUIRED FURTHER INSPECTION. THIS REPAIR IS CONSIDERED PRIMARY STRUCTURE IAW A320 SRM 51-11-12. ACCOMPLISHED BY AE TECH# 8617215. AE QC INSP# 183.