Service difficulty report · Door Sill · Airbus BD5001A11

Difficulty date
September 20, 2024
Submitted
September 24, 2024
Operation
Air carrier
Aircraft
N3085J
Make and model
Airbus BD5001A11
Aircraft serial
55132
Aircraft time
7,920 hours, 3,024 cycles
Part
Door Sill
Condition
Corroded
Location
Zone 100
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING HEAVY MAINTENANCE:FUSELAGE / FWD FUSELAGE / FWD CARGO DOOR SILL UNDERNEATHCARGO DOOR LOWER SCUFF PLATES / CORROSION – PERMANENT REPAIR; REFERENCES: /1/ AIRBUS CANADA REO-500-53-21-913 /2/ MX244. DESCRIPTION: DURING CURRENT CHECK ON N3085J (MSN: 55132) @ YMX, AVIANOR REPORTED CORROSION DAMAGE IN (4) AREAS ON THE FORWARD CARGO DOOR SILL (P/N C02313004-007) UNDERNEATH CARGO DOOR LOWER SCUFF PLATES. SEE REF /1/ FOR DETAILS. AIRBUS PROVIDED A PERMANENT REPAIR DISPOSITION VIA REO, REF /1/. THE PERMANENT REPAIR CONSISTS OF MODIFYING THE SILL, AND MANUFACTURING/INSTALLING A SPLICE AND A SHIM WITH ADDITIONAL FASTENERS. AVIANOR ACCOMPLISHED THIS REPAIR IN ACCORDANCE WITH REF /1/ REO WITHOUT DEVIATION. THIS EC AC24-1009-01 IS ISSUED TO ACCOMPLISH THE PERMANENT REPAIR PER REF /1/. EC AC24-1009-02 IS ISSUED TO TRACK THE POST REPAIR INSPECTIONS, DVI, (TH: 28,600 FC,55,700 FH AND INT: 9,400 FC, 18,330 FH) PER REF /1/ REO. SUBSTANTIATION: THIS PERMANENT REPAIR IS APPROVED PER REF /1/, REO AND IS CLASSIFIED AS MINOR IAW REF /2/, MX244 GUIDELINES** REV 01 ** ON 8/29/2024 AVIANOR REACHED OUT AND STATED THAT THIS REPAIR SHOULD BE CLASSIFIED AS MAJOR (WE HAD IT AS MINOR) IN JBU EC AND TC , SINCE CARGO DOOR SILL IS A PRIMARY STRUCTURE AND IT HAS BEEN SPLICED. AS A RESULT, REF. /2/ MX-244 IS REMOVED FROM THE ATTACHMENTS IN THIS EC AS IT IS NO LONGER NEEDED. THIS EC/TC AC24-1009-01 IS BEING REVISED TO CHANGE THE CLASSIFICATION OF THE REPAIR FROM MINOR TO MAJOR. (E/C: AC24-1009-01)

More about the Airbus BD-500-1A11