What was found
DURING HEAVY MAINTENANCE: INITIAL INSPECTION (CPCP FINDING): CORROSION ON LOWER SILL OF DOOR CUTOUT STRUCTURE AT AFT CARGO COMPARTMENT. CORROSION ON FINGER PLATE OF DOOR CUTOUT STRUCTURE AT AFT CARGO COMPARTMENT WAS REMOVED AND EVALUATED OUT LIMITS THEREFORE WAS REPLACED PER EMB 190 SRM 51-12-01, SRM 51-10-- 03, SRM 53-23-11/AD53,SRM 51-43-03 AND SRM 51-43-04.