What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE AT HOLE C OF JOGGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA; (RESOLVED ON W/O: 1311389 TASKCARD: NR-00056) REF AE W/O# 2024-214/1. N/R# 2024 - 446437. PERFORMED PERMANENT REPAIR ON HOLE C OF JOGGLE AREA ON FRAME 16 LH AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA I.A.W A320 SRM 53-11-12-300-012 PARAGRAPH 2.A. (1). FIGURE 001, FIGURE 004, FIGURE 005 AND FIGURE 008. DIA: 8.420 MM (0.3315 INCH). THIS REPAIR IS CLASSIFIED CATEGORY B AND MUST BE INSPECTED AT 6800FC (FH NOT RELEVANT) FROM TIME OF REPAIR EMBODIMENT AND SUBSEQUENT INSPECTION AT INTERVALS OF 5900 FC (FH NOT RELEVANT) IAW A320 SRI 53-11-12-205-008 TABLE 1. ACCOMPLISHED BY AE TECH# 8620918. AE TECH# 329. FUR-A320-53-01720 ASSIGNED.