What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON INTERCOSTAL FITTING LAYER AT THE UPPER AND LOWER INBOARD HOLES OF DOOR STOP FITTING 7 LOCATED FRAME 16 RH AT FWD GALLEY AREA; (RESOLVED ON W/O: 1311389 TASKCARD: NR-00055) REF AE W/O# 2024-214/1. N/R# 2024 - 446432. REMOVED AND REPLACED INTERCOSTAL FITTING LOCATED DOOR STOP FITTING 7 FRAME 16 RH AT FWD GALLEY AREA I.A.W. A320 SRM 53-11-12-300-010, A320 SRM 51-72-11, DWG D53114223 AND EC NO. 2022-02-11-FAA STEP 21. ACCOMPLISHED BY AE TECH# 8608018. AE QC INSP# 329.