What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE AT HOLE 6 OF JOGGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA; (RESOLVED ON W/O: 1311389 TASKCARD: NR-00054) REF AE W/O# 2024-214/1. N/R# 2024 - 446436. PERFORMED PERMANENT REPAIR ON HOLE 6 OF JOGGLE AREA LOC. ON FR16 LH AT LEVEL OF DOOR STOP FITTING 7 FWD GALLEY AREA IAW A320 SRM 53-11-12-300-012 PARAGRAPH 2.A.(1), FIGURE 001, FIGURE 004, FIGURE 005 AND FIGURE 008. DIA A = 12.445 MM (0.4899 INCH). THIS REPAIR IS CLASSIFIED CATEGORY B AND MUST BE INSPECTED AT 6800FC (FH NOT RELEVANT) FROM TIME OF REPAIR EMBODIMENT AND SUBSEQUENT INSPECTION AT INTERVALS OF 4700FC (FH NOT RELEVANT) IAW A320 SRI 53-11-12-205-008 TABLE 1. ACCOMPLISHED BY AE TECH# 8623121. AE QC INSP# 276. FUR-A320-53-01716 ASSIGNED.