What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON OPEN FASTENER HOLE LOC. ON FR.20 RH DOOR STOP FITTING 7 UPPER I/B HOLE. CRACK DEPTH IS 0.081 INCH APPROX; (RESOLVED ON W/O: 1318564 TASKCARD: NR-00041) REF AE WO 2024-275/1. N/R# 2024 - 538513. PERFORMED REPAIR ON FR.20 RH DOOR STOP FITTING 7 UPPER I/B HOLE IAW A320 SRM 53-11-12-300-010. THIS REPAIR IS CLASSIFIED CATEGORY B AND MUST BE INSPECTED AT 13400FC (FH NOT RELEVANT) FROM TIME OF REPAIR EMBODIMENT AND SUBSEQUENT INSPECTIONS AT INTERVALS OF 13400FC (FH NOT RELEVANT) I.A.W. A320 SRI 53-11-12-205-005. ACCOMPLISHED BY AE TECH# 8660318. AE QC INSP# 238. FUR-A320-53-01821 ASSIGNED.