What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 RH SIDE FROM HOLE A OF JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK DEPTH IS 0.084 INCH; (RESOLVED ON W/O: 1318564 TASKCARD: NR-00035) REF AE WO 2024-275/1. N/R# 2024 - 538558. PERFORMED PERMANENT REPAIR ON HOLE A FR 16 RH SIDE JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA I.A.W. A320 SRM 53-11-12-300-012 STEP 2.A.(1). DIA A= 10.355 MM (0.4076 INCH). THIS REPAIR IS CLASSIFIED CATEGORY B AND MUST BE INSPECTED AT 6800FC (FH NOT RELEVANT) FROM TIME OF REPAIR EMBODIMENT AND SUBSEQUENT INSPECTIONS AT INTERVALS OF 4100FC (FH NOT RELEVANT) I.A.W. A320 SRI 53-11-12-205-008 TABLE 1. ACCOMPLISHED BY AE TECH# 8671520. AE QC INSP# 220. FUR-A320-53-01811 ASSIGNED.