What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (AFT LH EEH DOOR 834) CRACK L=0.\130 INCH APPROX; (RESOLVED ON W/O: 1324769 TASKCARD: NR-00012) REMOVED AND REPLACED THE FRAME SEGMENTS ON THE EMERGENCY EXIT DOOR 834 I.A.W EC. A320-52-1144 AND A320 SRM 51-72-11.FOR INSTALLATION SEE TASK CARD A320-52-1144-03 ALL WORK ACCOMPLISHED ON AEROMAN WO 2024 263/1 NR 2024 649095.