What was found
DURING HEAVY MAINTENANCE: CORROSION FOUND ON UPPER SKIN OF FWD CARGO DOOR SURROUND STRUCTURE ANROUND SCUFF PLATE HOLES; (RESOLVED ON W/O: 1335461 TASKCARD: NR-00012) REF AVIANOR WO 102-J3 NR 3083 CORROSION REPAIRED ON UPPER SKIN OF FWD CARGO COMPARTMENT DOOR SURROUND STRUCTURE AROUND SCUFF PLATE HOLES IAW EC AC24-1398-01 AND REO 500-53-21-1009 TEMPORARY REPAIR DVI OF DISCREPANT AREA PER ANDTP BD500-A-J51-00-90-01AAA-018A-A AT INTERVALS NOT TO EXCEED 1000 FH THIS TEMP REPAIR IS VALID FOR 10,000 FH FROM INCORPORATION OF THIS REO.