What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON LOWER INB FASTENER HOLE OF DOOR STOP FITTING Ñ1 AREA FR 68 RH. CRACK DIRECTION 6 AND 12 O'CLOCK. CRACK D= 0.170 INCH; (RESOLVED ON W/O: 1347560 TASKCARD: NR-00040) REF AE WO 2024-413/1. N/R# 2024 - 749231. PERFORMED PERMANENT REPAIR ON FR68 RHS AT LEVEL DOOR STOP FITTING #1 IAW A320 SRM 53-41-12-300-011. THIS REPAIR IS CATEGORY B. AREA 1 AND AREA 3 MUST BE INSPECTED. INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT:60000 FC (FH NOT RELEVANT), SUBSEQUENT INSPECTIONS AT INTERVALS: TBD, METHOD OF INSPECTION: TBD IAW A320 SRI 53-41-12-205-010. ACCOMPLISHED BY AE TECH# 8632219. AE QC INSP# 238. FUR-A320-53-01951 ASSIGNED.