What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON UPPER INB FASTENER HOLE OF DOOR STOP FITTING Ñ7 AREA FR 66 RH. CRACK DIRECTION 5 AND 11 O'CLOCK. CRACK D= 0.170 INCH; (RESOLVED ON W/O: 1347560 TASKCARD: NR-00039) REF AE WO 2024-413/1. N/R# 2024 - 749229. PERFORMED PERMANENT REPAIR LOCATED ON FRAME 66 RH SIDE ON DOOR STOP FITTING #7 I.A.W A320 SRM 53-41-12-300-011.THIS PERMANENT REPAIR IS CATEGORY B AND REQUIRED REPETIVE INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT AT 15400 FC (FH NOT RELEVANT) SUBSEQUENT INSPECTION AT INTERVALS 5600 FC (FH NOT RELEVANT), INSPECTION METHOD HFEC (REFER TO NTM CHAPTER 51-10-08) I.A.W SRI 53-41-12-205-010. ACCOMPLISHED BY AE TECH# 8632219. AE QC INSP# 238. FUR-A320-53-01950 ASSIGNED.