What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON LOWER OUTB FASTENER HOLE OF DOOR STOP FITTING Ñ1 AREA FR 68 LH. CRACK DIRECTION 10 O'CLOCK. CRACK D= 0.170 INCH; (RESOLVED ON W/O: 1347560 TASKCARD: NR-00038) REF AE WO 2024-413/1.N/R# 2024 - 749228. PERFORMED PERMANENT REPAIR ON FR68 LHS AT LEVEL DOOR STOP FITTING #1 IAW A320 SRM 53-41-12-300-011. THIS REPAIR IS CATEGORY B. AREA 2 MUST BE INSPECTED. INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT: 37900FC (FH NOT RELEVANT), SUBSEQUENT INSPECTIONS AT INTERVALS: 5300 FC(FH NOT RELEVANT), METHOD OF INSPECTION: HFEC (REFER TO NTM CHAPTER 51-10-08 IAW A320 SRI 53-41-12-205-010 TABLE 6. ACCOMPLISHED BY AE TECH # 8600815. AE QC INSP# 360. FUR-A320-53-01949 ASSIGNED.