What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON LOWER INB FASTENER HOLE OF DOOR STOP FITTING Ñ1 AREA FR 68 LH. CRACK DIRECTION 5 AND 11 OCLOCK. CRACK D= 0.170 INCH; (RESOLVED ON W/O: 1347560 TASKCARD: NR-00036) REF AEM WO 2024-413/1, NR 2024-749227, PERFORMED PERMANENT REPAIR ON FR68 LHS AT LEVEL DOOR STOP FITTING #1 IAW A320 SRM SRM 53-41-12-300-011. THIS REPAIR IS CATEGORY B. AREA 1 AND AREA 3 MUST BE INSPECTED. INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT:60000 FC (FH NOT RELEVANT), SUBSEQUENT INSPECTIONS AT INTERVALS: TBD, METHOD OF INSPECTION: TBD IAW A320 SRI 53-41-12-205-010 TABLE 6. ACC BY #8600815, INSP BY AE QC # 360.