What was found
DURING HEAVY MAINTENANCE: SEVERAL CRACK INDICATIONS FOUND ON BOTH FRAME SEGMENTS 1 OF THE FWD RH SIDE OVERWING EMERGENCY EXIT HATCHDOOR 843. MAXIMUM CRACK LENGTH: 0. 300 INCHES; (RESOLVED ON W/O: 1353728 TASKCARD: NR-00035) EMERGENCY EXIT / OVERWING EMERGENCY EXIT HATCH (FWD RH EEH) FRAME / REINFORCE DOOR STRUCTURE - MODIFICATION I.A.W. EC A320-52-1144 TASK CARD A320-52-1144-02 ALL WORK ACCOMPLISHED ON AEROMAN WO 2025 178/1 NR 245313.